Typical applications are at thermal
power plants, cement and lime kilns and waste to energy boilers etc. in
the area of flames and flue gas
Thermo elements in the PiT FluxStylus
are specified suiting to the specific application. Possible
temperatures range from ambient temperatures to a max. of 1600°C (2910
°F).
Works
Can be used as a Total Radiation
Sensor for single measurements (analysis of flame temperatures and
frequencies) or as emission tomography measurement (on arrangement of
several sensors plane and distributed in the room)
Features:
Calibrated at a black body radiator
Measurements from 5 to 9 different positions per sensor
Approx 5 cm in diameter, length project depending
Comes with air hose (1 to 5 m²/h per sensor), connection cables and field cabinet for connection to DCS or Powitec Server
Robust German design = Low maintenance
Optionally:
Pneumatic Automatic Anti Slagging Unit
Sophisticated data displaying tools
Sophisticated data processing
Connection with PCS data = Correlations show variations